Uncompromising treatment of industrial effluents
Maximum reduction of pollutants with a simple, reliable and eco-responsible process.
Reduction of polluting loads
Energy saving and cost reduction
Valorization of sludge and optimization of space
Positioning of VAL INDUS
The VAL INDUS can be positioned at different levels in the industrial water cycle. It can be located upstream on filtration, in pre-treatment before sending to a wastewater treatment plant or in pre-membrane treatment.
The advantages of VAL INDUS vs. standard treatment processes
CAPEX
- Remplacement chaîne de procédés mono-fonctions
- Réduction investissement génie civil
OPEX
- Savings Of energy (division by 2 to 3)
-Few consumables (vs washing and changing filters)
Low ground footprint
Up to 5 times lower - with sound vertical design.
Robustesse et facilité d’utilisation
- Remote control
- No moving parts susceptible to wear or corrosion
Environmentally friendly
- Water loss < 1% flow vs. 30 à 40 %
- Longue lifetimes
- Sludge recovery (siccité > 15%) avec pouvoir méthanogène
Simplified synopsis of VAL INDUS
Process test (by sample or via VAL SKID)
Each effluent has its own specificities (volumes, charges, temperature, pH...). In this context, Coldep proposes to recover a representative sample of the effluent to be treated and to test the VAL technology to assess its abatement performance in relation to the objectives targeted.
1. Status/objectives
Volume, location
Other processes in place...
Target allowances (MES, dbo, dco, others)
2. Sample
5 liters for jar test
500-1000 liters for pilot tests
3. Conducting tests
Sapoval partnership (albi)
Qualification real conditions
4. Sharing results
Report: test results & performances
Possible advantage: complementary process
5. Quantified commitments
On performance
On capex
And on Opex
6. Project launch
Integrative choice
Planning
Water launch
“VAL INDUS has replaced a flotation process that no longer offered the high level of performance desired to treat effluents from our plant. In a very limited floor space, this new process allows us to meet the desired rejection standards. It also valorizes sludge by methanization thanks to a dryness rate twice as high as before. Remote control finally gives us security and an appreciable guarantee of performance.”
GOZOKI, Tino House
Gigean Industrial Site (34)
Problem
Treatment requirement: 150 m³/ j (+/- 5 m³/h)
Sludge produced with a dryness of 8 - 14% (500 t/year)
Objectives
Valorization, methanization, waste
VAL INDUS (x2 in series)
Coagulants, flocculants and pH neutralization with soda: automated system under control
Results
Sludge dried 14-15% (500 tons wet/year)
+ 88% reduction in DCO, DBO and MES
Size/Type of VAL INDUS
Model | Optimal flow m3/h | Height | Footspace | Energy consumption |
---|---|---|---|---|
VAL INDUS 900 | 10 | 4 m | 5 m² | 2-3 KW/H |
VAL INDUS 1400 | 20 | 4.5 m | 12 m² | 4-5 KW/H |
VAL INDUS 2000 | 40 | 5.5 m | 20 m² | 6-8 KW/H |
VAL SKID: PILOT TESTING, DEPLOYMENT, AND RENTAL OPTIONS
Coldep provides mobile pilot units in containerized or skid-mounted configurations. These allow for on-site testing and validation of technical decisions from the design phase, supplementing the preliminary lab tests conducted with the VAL PILOT.
Learn moreGet in touch with our team
See the effectiveness of VAL in action. Let's discuss your project to develop the VAL solution (alone or in addition) that corresponds to your problems and your environmental and economic performance objectives.
Contact